Lab 215 

Working experience:

- Using a VME 16 channel scaler (V560N/E models).

Hardware (and power-on) configuration: rotary switches and internal jumpers.

Addressing and data transfer capability.

Reading the module identifier words (first 3 words): bitwise operations with masks and bit shifting.

Reading the counters with A24 addressing and D16/D32 mode with an external NIM signal. 


Ultime modifiche: martedì, 21 febbraio 2023, 16:40