VME first level trigger 10/05/24 (14:00 - 18:00)
Aggregazione dei criteri
Lab 215
Working experience:
VME V1718/2718 first level trigger
First complete cycle of electronics control and data acquisition via VME controller V1718 Working experience:
- Build a logic circuit to make VME_DAQ_Control.vi work
- Verify the correctness of the program with the aid of a visual scaler
- Modify the vi routine for the readout of TAC + QDC
- Understand other vi's form the CAENVMElib.lib library
- Modify the program in order to make it work with a VME Scaler (and control the Veto!)
http://wwwusers.ts.infn.it/~rui/univ/Acquisizione_Dati/Lezioni/XIV%20-%201st%20Level%20Trigger/
Ultime modifiche: venerdì, 10 maggio 2024, 14:19