VME R/W Cycle, NIM input lines 23/04/25 (14:00 - 18:00)
                                    Completion requirements
                                    
                        
                        Lab 215
Working experience:
- Using a VME 8/16 channel scaler (V560N V2495 models). 
Hardware (and power-on) configuration: rotary switches and internal jumpers. 
Addressing and data transfer capability. 
Reading the module identifier words (first 3 words): bitwise operations with masks and bit shifting. 
Reading the counters with A24 addressing and D16/D32 mode with an external NIM signal.  